{"title":"Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (Two-Door Enclosures)","description":"\u003cp\u003eFree-Standing and Floor-Mounted Enclosures \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (One, Two, Three and  Multi-Door Enclosures) \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (Two-Door Enclosures)\u003c\/p\u003e","products":[{"product_id":"sce-72xd5418","title":"SCE-72XD5418 - 2DR XD Enclosure","description":"\u003cp\u003e2DR XD Enclosure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Free-Standing and Floor-Mounted Enclosures \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (One, Two, Three and  Multi-Door Enclosures) \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (Two-Door Enclosures)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eSCE-72XD5418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003e2DR XD Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e53.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e18.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrice Code\u003c\/th\u003e\n\u003ctd\u003eA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList Price\u003c\/th\u003e\n\u003ctd\u003e$5,073.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Page\u003c\/th\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Ship Weight\u003c\/th\u003e\n\u003ctd\u003e740.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.125 In. carbon steel.\u003c\/li\u003e\n\u003cli\u003eSeams continously welded and ground smooth.\u003c\/li\u003e\n\u003cli\u003eFlange trough collar around all sides of door opening.\u003c\/li\u003e\n\u003cli\u003eBody stiffeners in large enclosures for extra rigidity.\u003c\/li\u003e\n\u003cli\u003eHeavy duty lifting eyes anchor into reinforced top.\u003c\/li\u003e\n\u003cli\u003eRemovable center post to permit easy sub-panel installation.\u003c\/li\u003e\n\u003cli\u003eConcealed hinges.\u003c\/li\u003e\n\u003cli\u003eBlack zinc die cast coinproof\/padlocking handle on main door with black zinc die cast padlocking handle on slave doors.\u003c\/li\u003e\n\u003cli\u003e3-point latching mechanism.\u003c\/li\u003e\n\u003cli\u003eLarge removable print pockets.\u003c\/li\u003e\n\u003cli\u003ePour in place oil \u0026amp; water resistant gasket\u003c\/li\u003e\n\u003cli\u003eRemovable panels are mounted on collar studs.\u003c\/li\u003e\n\u003cli\u003eDefeater on master door requires a screwdriver to open.\u003c\/li\u003e\n\u003cli\u003eExternal disconnect defeater requires screwdriver for access.\u003c\/li\u003e\n\u003cli\u003eGround stud on door \u0026amp; body\u003c\/li\u003e\n\u003cli\u003eProvisions for light kit.\u003c\/li\u003e\n\u003cli\u003eHole plugs provided to seal holes in bottom of enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eDesigned to house the main power supply in external enclosure on the right side of main enclosure, keeping the live side of the power supply separate from the primary electrical equipment. Provides protection from dirt, dust, oil and water and can house most standard type disconnects. For outdoor application a drip shield and drain vent is recommended. For Details about the design, performance expectations, applications and design suggestions -\u003c\/p\u003e\n\u003ch3\u003eFinish\u003c\/h3\u003e\n\u003cp\u003eANSI-61 gray powder coating inside and out. Sub-panels are powder coated white. Part numbers ending in \"G\" have galvanized subpanels installed.\u003c\/p\u003e\n\u003ch3\u003eIndustry Standards - (IS4)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA Type 3R, 4, 12 and Type 13\u003c\/li\u003e\n\u003cli\u003eUL Listed Type 3R, 4 and 12\u003c\/li\u003e\n\u003cli\u003eCSA Type 3R, 4 and 12\u003c\/li\u003e\n\u003cli\u003eIEC 60529\u003c\/li\u003e\n\u003cli\u003eIP 66\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cp\u003eFor use with 30 to 200 Amp Flange mount disconnect Square D, Allen Bradley, and some Eaton\/Cutler Hammer operating handles. Disconnect switch (or circuit breaker) and operating mechanism are not furnished with enclosure. *Part numbers ending in \"G\" have galvanized sub-panels installed. Special Instructions apply for IS3, IS4 and IS6 to maintain the environmental rating of Type 3R for these parts. Instructions are located on the enclosure door. Drip shield is required on IS3, drip shield is recommended on IS4 and IS6. Drain holes are required on all.\u003c\/p\u003e","brand":"Saginaw Control \u0026 Engineering","offers":[{"title":"Default Title","offer_id":49416614379758,"sku":"SCE-72XD5418","price":5073.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/4208\/5870\/files\/sce-72xd5418.png?v=1786672472"},{"product_id":"sce-72xd5418g","title":"SCE-72XD5418G - 2DR XD Enclosure","description":"\u003cp\u003e2DR XD Enclosure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Free-Standing and Floor-Mounted Enclosures \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (One, Two, Three and  Multi-Door Enclosures) \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (Two-Door Enclosures)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eSCE-72XD5418G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003e2DR XD Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e53.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e18.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrice Code\u003c\/th\u003e\n\u003ctd\u003eA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList Price\u003c\/th\u003e\n\u003ctd\u003e$5,132.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Page\u003c\/th\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Ship Weight\u003c\/th\u003e\n\u003ctd\u003e740.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.125 In. carbon steel.\u003c\/li\u003e\n\u003cli\u003eSeams continously welded and ground smooth.\u003c\/li\u003e\n\u003cli\u003eFlange trough collar around all sides of door opening.\u003c\/li\u003e\n\u003cli\u003eBody stiffeners in large enclosures for extra rigidity.\u003c\/li\u003e\n\u003cli\u003eHeavy duty lifting eyes anchor into reinforced top.\u003c\/li\u003e\n\u003cli\u003eRemovable center post to permit easy sub-panel installation.\u003c\/li\u003e\n\u003cli\u003eConcealed hinges.\u003c\/li\u003e\n\u003cli\u003eBlack zinc die cast coinproof\/padlocking handle on main door with black zinc die cast padlocking handle on slave doors.\u003c\/li\u003e\n\u003cli\u003e3-point latching mechanism.\u003c\/li\u003e\n\u003cli\u003eLarge removable print pockets.\u003c\/li\u003e\n\u003cli\u003ePour in place oil \u0026amp; water resistant gasket\u003c\/li\u003e\n\u003cli\u003eRemovable panels are mounted on collar studs.\u003c\/li\u003e\n\u003cli\u003eDefeater on master door requires a screwdriver to open.\u003c\/li\u003e\n\u003cli\u003eExternal disconnect defeater requires screwdriver for access.\u003c\/li\u003e\n\u003cli\u003eGround stud on door \u0026amp; body\u003c\/li\u003e\n\u003cli\u003eProvisions for light kit.\u003c\/li\u003e\n\u003cli\u003eHole plugs provided to seal holes in bottom of enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eDesigned to house the main power supply in external enclosure on the right side of main enclosure, keeping the live side of the power supply separate from the primary electrical equipment. Provides protection from dirt, dust, oil and water and can house most standard type disconnects. For outdoor application a drip shield and drain vent is recommended. For Details about the design, performance expectations, applications and design suggestions -\u003c\/p\u003e\n\u003ch3\u003eFinish\u003c\/h3\u003e\n\u003cp\u003eANSI-61 gray powder coating inside and out. Sub-panels are powder coated white. Part numbers ending in \"G\" have galvanized subpanels installed.\u003c\/p\u003e\n\u003ch3\u003eIndustry Standards - (IS4)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA Type 3R, 4, 12 and Type 13\u003c\/li\u003e\n\u003cli\u003eUL Listed Type 3R, 4 and 12\u003c\/li\u003e\n\u003cli\u003eCSA Type 3R, 4 and 12\u003c\/li\u003e\n\u003cli\u003eIEC 60529\u003c\/li\u003e\n\u003cli\u003eIP 66\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cp\u003eFor use with 30 to 200 Amp Flange mount disconnect Square D, Allen Bradley, and some Eaton\/Cutler Hammer operating handles. Disconnect switch (or circuit breaker) and operating mechanism are not furnished with enclosure. *Part numbers ending in \"G\" have galvanized sub-panels installed. Special Instructions apply for IS3, IS4 and IS6 to maintain the environmental rating of Type 3R for these parts. Instructions are located on the enclosure door. Drip shield is required on IS3, drip shield is recommended on IS4 and IS6. Drain holes are required on all.\u003c\/p\u003e","brand":"Saginaw Control \u0026 Engineering","offers":[{"title":"Default Title","offer_id":49416614674670,"sku":"SCE-72XD5418G","price":5132.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/4208\/5870\/files\/sce-72xd5418g.png?v=1786672475"},{"product_id":"sce-72xd6618","title":"SCE-72XD6618 - 2DR XD Enclosure","description":"\u003cp\u003e2DR XD Enclosure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Free-Standing and Floor-Mounted Enclosures \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (One, Two, Three and  Multi-Door Enclosures) \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (Two-Door Enclosures)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eSCE-72XD6618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003e2DR XD Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e65.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e18.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrice Code\u003c\/th\u003e\n\u003ctd\u003eA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList Price\u003c\/th\u003e\n\u003ctd\u003e$5,540.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Page\u003c\/th\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Ship Weight\u003c\/th\u003e\n\u003ctd\u003e865.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.125 In. carbon steel.\u003c\/li\u003e\n\u003cli\u003eSeams continously welded and ground smooth.\u003c\/li\u003e\n\u003cli\u003eFlange trough collar around all sides of door opening.\u003c\/li\u003e\n\u003cli\u003eBody stiffeners in large enclosures for extra rigidity.\u003c\/li\u003e\n\u003cli\u003eHeavy duty lifting eyes anchor into reinforced top.\u003c\/li\u003e\n\u003cli\u003eRemovable center post to permit easy sub-panel installation.\u003c\/li\u003e\n\u003cli\u003eConcealed hinges.\u003c\/li\u003e\n\u003cli\u003eBlack zinc die cast coinproof\/padlocking handle on main door with black zinc die cast padlocking handle on slave doors.\u003c\/li\u003e\n\u003cli\u003e3-point latching mechanism.\u003c\/li\u003e\n\u003cli\u003eLarge removable print pockets.\u003c\/li\u003e\n\u003cli\u003ePour in place oil \u0026amp; water resistant gasket\u003c\/li\u003e\n\u003cli\u003eRemovable panels are mounted on collar studs.\u003c\/li\u003e\n\u003cli\u003eDefeater on master door requires a screwdriver to open.\u003c\/li\u003e\n\u003cli\u003eExternal disconnect defeater requires screwdriver for access.\u003c\/li\u003e\n\u003cli\u003eGround stud on door \u0026amp; body\u003c\/li\u003e\n\u003cli\u003eProvisions for light kit.\u003c\/li\u003e\n\u003cli\u003eHole plugs provided to seal holes in bottom of enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eDesigned to house the main power supply in external enclosure on the right side of main enclosure, keeping the live side of the power supply separate from the primary electrical equipment. Provides protection from dirt, dust, oil and water and can house most standard type disconnects. For outdoor application a drip shield and drain vent is recommended. For Details about the design, performance expectations, applications and design suggestions -\u003c\/p\u003e\n\u003ch3\u003eFinish\u003c\/h3\u003e\n\u003cp\u003eANSI-61 gray powder coating inside and out. Sub-panels are powder coated white. Part numbers ending in \"G\" have galvanized subpanels installed.\u003c\/p\u003e\n\u003ch3\u003eIndustry Standards - (IS3)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA Type 3R, 12 and Type 13\u003c\/li\u003e\n\u003cli\u003eUL Listed Type 3R and 12\u003c\/li\u003e\n\u003cli\u003eCSA Type 3R and 12\u003c\/li\u003e\n\u003cli\u003eIEC 60529\u003c\/li\u003e\n\u003cli\u003eIP 55\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cp\u003eFor use with 30 to 200 Amp Flange mount disconnect Square D, Allen Bradley, and some Eaton\/Cutler Hammer operating handles. Disconnect switch (or circuit breaker) and operating mechanism are not furnished with enclosure. *Part numbers ending in \"G\" have galvanized sub-panels installed. Special Instructions apply for IS3, IS4 and IS6 to maintain the environmental rating of Type 3R for these parts. Instructions are located on the enclosure door. Drip shield is required on IS3, drip shield is recommended on IS4 and IS6. Drain holes are required on all.\u003c\/p\u003e","brand":"Saginaw Control \u0026 Engineering","offers":[{"title":"Default Title","offer_id":49416615264494,"sku":"SCE-72XD6618","price":5540.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/4208\/5870\/files\/sce-72xd6618.png?v=1786672483"},{"product_id":"sce-72xd7818","title":"SCE-72XD7818 - 2DR XD Enclosure","description":"\u003cp\u003e2DR XD Enclosure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Free-Standing and Floor-Mounted Enclosures \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (One, Two, Three and  Multi-Door Enclosures) \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (Two-Door Enclosures)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eSCE-72XD7818\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003e2DR XD Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e72.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e77.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e18.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrice Code\u003c\/th\u003e\n\u003ctd\u003eA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList Price\u003c\/th\u003e\n\u003ctd\u003e$6,257.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Page\u003c\/th\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Ship Weight\u003c\/th\u003e\n\u003ctd\u003e960.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.125 In. carbon steel.\u003c\/li\u003e\n\u003cli\u003eSeams continously welded and ground smooth.\u003c\/li\u003e\n\u003cli\u003eFlange trough collar around all sides of door opening.\u003c\/li\u003e\n\u003cli\u003eBody stiffeners in large enclosures for extra rigidity.\u003c\/li\u003e\n\u003cli\u003eHeavy duty lifting eyes anchor into reinforced top.\u003c\/li\u003e\n\u003cli\u003eRemovable center post to permit easy sub-panel installation.\u003c\/li\u003e\n\u003cli\u003eConcealed hinges.\u003c\/li\u003e\n\u003cli\u003eBlack zinc die cast coinproof\/padlocking handle on main door with black zinc die cast padlocking handle on slave doors.\u003c\/li\u003e\n\u003cli\u003e3-point latching mechanism.\u003c\/li\u003e\n\u003cli\u003eLarge removable print pockets.\u003c\/li\u003e\n\u003cli\u003ePour in place oil \u0026amp; water resistant gasket\u003c\/li\u003e\n\u003cli\u003eRemovable panels are mounted on collar studs.\u003c\/li\u003e\n\u003cli\u003eDefeater on master door requires a screwdriver to open.\u003c\/li\u003e\n\u003cli\u003eExternal disconnect defeater requires screwdriver for access.\u003c\/li\u003e\n\u003cli\u003eGround stud on door \u0026amp; body\u003c\/li\u003e\n\u003cli\u003eProvisions for light kit.\u003c\/li\u003e\n\u003cli\u003eHole plugs provided to seal holes in bottom of enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eDesigned to house the main power supply in external enclosure on the right side of main enclosure, keeping the live side of the power supply separate from the primary electrical equipment. Provides protection from dirt, dust, oil and water and can house most standard type disconnects. For outdoor application a drip shield and drain vent is recommended. For Details about the design, performance expectations, applications and design suggestions -\u003c\/p\u003e\n\u003ch3\u003eFinish\u003c\/h3\u003e\n\u003cp\u003eANSI-61 gray powder coating inside and out. Sub-panels are powder coated white. Part numbers ending in \"G\" have galvanized subpanels installed.\u003c\/p\u003e\n\u003ch3\u003eIndustry Standards - (IS3)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA Type 3R, 12 and Type 13\u003c\/li\u003e\n\u003cli\u003eUL Listed Type 3R and 12\u003c\/li\u003e\n\u003cli\u003eCSA Type 3R and 12\u003c\/li\u003e\n\u003cli\u003eIEC 60529\u003c\/li\u003e\n\u003cli\u003eIP 55\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cp\u003eFor use with 30 to 200 Amp Flange mount disconnect Square D, Allen Bradley, and some Eaton\/Cutler Hammer operating handles. Disconnect switch (or circuit breaker) and operating mechanism are not furnished with enclosure. *Part numbers ending in \"G\" have galvanized sub-panels installed. Special Instructions apply for IS3, IS4 and IS6 to maintain the environmental rating of Type 3R for these parts. Instructions are located on the enclosure door. Drip shield is required on IS3, drip shield is recommended on IS4 and IS6. Drain holes are required on all.\u003c\/p\u003e","brand":"Saginaw Control \u0026 Engineering","offers":[{"title":"Default Title","offer_id":49416615395566,"sku":"SCE-72XD7818","price":6257.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/4208\/5870\/files\/sce-72xd7818.png?v=1786672487"},{"product_id":"sce-90xd7818g","title":"SCE-90XD7818G - 2DR XD Enclosure","description":"\u003cp\u003e2DR XD Enclosure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Free-Standing and Floor-Mounted Enclosures \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (One, Two, Three and  Multi-Door Enclosures) \u0026gt; Heavy Duty Free-Standing Enclosures with External Disconnect Enclosure Installed (Two-Door Enclosures)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eSCE-90XD7818G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003e2DR XD Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e90.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e77.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e18.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrice Code\u003c\/th\u003e\n\u003ctd\u003eA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList Price\u003c\/th\u003e\n\u003ctd\u003e$7,492.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog Page\u003c\/th\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Ship Weight\u003c\/th\u003e\n\u003ctd\u003e1,175.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0.125 In. carbon steel.\u003c\/li\u003e\n\u003cli\u003eSeams continously welded and ground smooth.\u003c\/li\u003e\n\u003cli\u003eFlange trough collar around all sides of door opening.\u003c\/li\u003e\n\u003cli\u003eBody stiffeners in large enclosures for extra rigidity.\u003c\/li\u003e\n\u003cli\u003eHeavy duty lifting eyes anchor into reinforced top.\u003c\/li\u003e\n\u003cli\u003eRemovable center post to permit easy sub-panel installation.\u003c\/li\u003e\n\u003cli\u003eConcealed hinges.\u003c\/li\u003e\n\u003cli\u003eBlack zinc die cast coinproof\/padlocking handle on main door with black zinc die cast padlocking handle on slave doors.\u003c\/li\u003e\n\u003cli\u003e3-point latching mechanism.\u003c\/li\u003e\n\u003cli\u003eLarge removable print pockets.\u003c\/li\u003e\n\u003cli\u003ePour in place oil \u0026amp; water resistant gasket\u003c\/li\u003e\n\u003cli\u003eRemovable panels are mounted on collar studs.\u003c\/li\u003e\n\u003cli\u003eDefeater on master door requires a screwdriver to open.\u003c\/li\u003e\n\u003cli\u003eExternal disconnect defeater requires screwdriver for access.\u003c\/li\u003e\n\u003cli\u003eGround stud on door \u0026amp; body\u003c\/li\u003e\n\u003cli\u003eProvisions for light kit.\u003c\/li\u003e\n\u003cli\u003eHole plugs provided to seal holes in bottom of enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eDesigned to house the main power supply in external enclosure on the right side of main enclosure, keeping the live side of the power supply separate from the primary electrical equipment. Provides protection from dirt, dust, oil and water and can house most standard type disconnects. For outdoor application a drip shield and drain vent is recommended. For Details about the design, performance expectations, applications and design suggestions -\u003c\/p\u003e\n\u003ch3\u003eFinish\u003c\/h3\u003e\n\u003cp\u003eANSI-61 gray powder coating inside and out. Sub-panels are powder coated white. Part numbers ending in \"G\" have galvanized subpanels installed.\u003c\/p\u003e\n\u003ch3\u003eIndustry Standards - (IS3)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA Type 3R, 12 and Type 13\u003c\/li\u003e\n\u003cli\u003eUL Listed Type 3R and 12\u003c\/li\u003e\n\u003cli\u003eCSA Type 3R and 12\u003c\/li\u003e\n\u003cli\u003eIEC 60529\u003c\/li\u003e\n\u003cli\u003eIP 55\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNotes\u003c\/h3\u003e\n\u003cp\u003eFor use with 30 to 200 Amp Flange mount disconnect Square D, Allen Bradley, and some Eaton\/Cutler Hammer operating handles. Disconnect switch (or circuit breaker) and operating mechanism are not furnished with enclosure. *Part numbers ending in \"G\" have galvanized sub-panels installed. Special Instructions apply for IS3, IS4 and IS6 to maintain the environmental rating of Type 3R for these parts. Instructions are located on the enclosure door. Drip shield is required on IS3, drip shield is recommended on IS4 and IS6. Drain holes are required on all.\u003c\/p\u003e","brand":"Saginaw Control \u0026 Engineering","offers":[{"title":"Default Title","offer_id":49416656158958,"sku":"SCE-90XD7818G","price":7492.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/4208\/5870\/files\/sce-90xd7818g.png?v=1786673202"}],"url":"https:\/\/panelautomation.com\/collections\/saginaw-heavy-duty-free-standing-enclosures-with-external-disconnect-enclosure-installed-two-door-enclosures-518.oembed","provider":"Panel Automation","version":"1.0","type":"link"}